ver : pa_1 update : 2012.03.09 led power aqf40c series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications model no. aqf40c-12s aqf40c -15s aqf40c -24s aqf40c -48s aqf40c -54s max output wattage (w) 40w voltage 90-305 vac or 120-430 vdc frequency (hz) 47-63 hz current (full load) 0.43 a max. (115 vac) / 0.24 a max. (230 vac) / 0.23 a max. (277 vac) inrush current (<2ms) 40 a max. (115 vac) / 70 a max. (230 vac) leakage current <0.75 ma max. input power factor pf>0.97 (115 vac) / pf>0.9 (230 vac) at full load voltage (v.dc.) 12v 15v 24v 48v 54v constant current range (v.dc.) 6 ~ 12v 7.5 ~ 15v 12 ~ 24v 24 ~ 48v 27 ~ 54v voltage accuracy 2% current (convection) (ma) max 3333 2666 1666 833 740 current adj range (ma) 1667 ~ 3333 1333 ~ 2666 833 ~ 1666 417 ~ 833 370 ~ 740 voltage adj range (v.dc.) 10.8 ~ 13.5v 13.5 ~ 17v 22 ~ 27v 43 ~ 53v 49 ~ 58v line regulation 1% load regulation 1% minimum load maximum capacitive load ripple & noise (max.) 150mvp-p 150mvp-p 200mvp-p 300mvp-p 300mvp-p efficiency (typ.) 85% 85% 87% 88% 88% hold-up time 25 ms min. output switching frequency over power protection auto recovery over voltage protection auto recovery overt temperature protection auto recovery protection short circuit protection auto recovery input-output (v.ac) 3750v input-fg (v.ac) 1880v isolation output-fg . (v.ac) 500v operating temperature -40c?+70c (with derating) storage temperature -40c?+85c temperature coefficient 0.02%/c ( 0~50c ) humidity 95% rh mtbf >100,000 h @ 25c (mil-hdbk-217f) environment vibration 10~500hz, 5g 10min./1cycle, 60min. each along x, y, z axes. key features ? open frame led power supply ? universal input: 90-305 vac or 120-430 vdc ? three in one dimming function (1~10vdc & pwm signal or resistance) ? bulit-in active pfc function ? free air convection ? high reliability ? with constant current & constant voltage ? output voltage and constant current level can be adjusted through inte rnal potential meter ? led power application ? 3-years product warranty 1. all specifications valid at normal input voltage, full load and +25c after warm-up time unless otherwise stated. 2. ripple & noise are measured a t 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor.
ver : pa_1 update : 2012.03.09 led power aqf40c series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- model no. aqf40c-12s aqf40c -15s aqf40c -24s aqf40c -48s aqf40c -54s dimension (l x w x h) 5.9 x 1.97 x 1.18 inches (150.0 x 50.0 x 30.0 mm ) tolerance 0.5 mm weight g physical cooling method free air convection safety agency approvals ul8750 iec / en 61347-2-13 iec / en 61347-1 emi (conducted & radiated emission) en 55015 class b (pending) ems (noise immunity) en 61547 (pending) emc surge 2kv l-l, 4kv l-e mechanical dimension ( top view ) derating pin# single 1 ac in (l) 2 ac in (n) 3 fg 4 +dc out 5 -dc out block diagram 1. all specifications valid at nom inal input voltage, full load and +25c after warm-up time unless otherwise stated. 2. ripple & noise are measured a t 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor.
ver : pa_1 update : 2012.03.09 led power aqf40c series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- efficiency versus load aqf40c-12s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) input voltage (v) 277 305 efficiency (%) load (%) 0 10 20 30 40 50 115v (%) 230v (%) load (%) 60 70 80 90 100 115v (%) 230v (%) aqf40c -15s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) input voltage (v) 277 305 efficiency (%) load (%) 0 10 20 30 40 50 115v (%) 230v (%) load (%) 60 70 80 90 100 115v (%) 230v (%)
ver : pa_1 update : 2012.03.09 led power aqf40c series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -4- efficiency versus load aqf40c -24s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) input voltage (v) 277 305 efficiency (%) load (%) 0 10 20 30 40 50 115v (%) 230v (%) load (%) 60 70 80 90 100 115v (%) 230v (%) aqf40c -48s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) input voltage (v) 277 305 efficiency (%) load (%) 0 10 20 30 40 50 115v (%) 230v (%) load (%) 60 70 80 90 100 115v (%) 230v (%)
ver : pa_1 update : 2012.03.09 led power aqf40c series 40 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -5- efficiency versus load aqf40c -54s vin vs efficiency load vs efficiency input voltage (v) 90 115 180 230 264 efficiency (%) input voltage (v) 277 305 efficiency (%) load (%) 0 10 20 30 40 50 115v (%) 230v (%) load (%) 60 70 80 90 100 115v (%) 230v (%)
|